Customization: | Available |
---|---|
Task: | Adjust |
Structure: | Open-Loop |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SCR Power Regulator SCR Control Heater
NO. | Mark | Functional Description |
1 | P+ | Reference power supply +5V:Feed reference for external potentiometers |
2 | AI1 | Current analog input port1:DC0~20420mA(inputimpedance 1252),with 4-terminal GND to form an input loop. |
3 | AI2 | Voltage analog input port 2: 0~5V input/potentiometer input (center tap)/DC0~10V, and GND form the input circuit. 0~5V 0~10V no need to connect P+ |
4 | GND | Sianal common ground: analog signal negative terminal, switch signal common terminal |
5 | PWM | Signal Analog,PWM Input Port |
6 | 4-20mA Output | 4-20mA output+ |
7 | COM | 4-20mA output- |
8 | A | RS485 communication port,RS485+ |
9 | B | RS485 communication port,RS485- |
10 | SW1 | External start/stop control terminal:SW1and 12 terminal GND constitute the start/stop, when the two terminals are closed,the adjuster work |
11 | SW2 | Analog input port selection:SW2 and terminal 12 GND,closed to select analog input port 2; disconnected to selectthe input port |
12 | GND | Signal common ground:analog signal negative terminal,switch signal common terminal |
13 | NO | Output relay 1:according to the menu A basic parameters A07 function selection can be used as an output signal,or fault alarm output signal No.,load capacity AC240V/5A,DC24V/5A NO:Normally open NC:Normally closed |
14 | COM | |
15 | NC | |
16 | NO | Output relay 2:according to the menu A basic parameters A08 function selection can be used as an output signal,or fault alarm output signal No.,load capacity AC240V/5A,DC24V/5A NO:Normally open NC:Normally closed |
17 | COM | |
18 | NC | |
19 | L | External AC 220V power supply |
20 | N |
Basic application wiring: 4~20mA control signal input positive to terminal 2 Al1, negative to terminal
4 GND. start terminals 10 and 12 have been factory connected, default power on start.
lf you need to install a starting switch on the control cabinet, you can make 10 and 12 as a switch.
Safety reminder: it is recommended to use the alarm output function of the power conditioner when
designing the electrical wiring, the power conditioner for the load and power supply has a perfect
alarm function, when there is any abnormality, it can be the first time alarm output.
It is widely used in lighting equipment,temperature control equipment and other power automatic adjustment occasions. Noted: Can't control AC motor speed!!!
Note: This type of voltage regulating three phase scr is not suitable for inductive loads such as transformers and motors.