SCR Power Regulator
| Why Choose Our Power Regulator | |
| Multiple Function Control Modes | Constant power control mode |
| Constantcurrent control mode | |
| Open loop control mode | |
| Cycle zero crossing control mode | |
| Multiple Protection Functions | Power supply phaseloss protectionRadiatoroverheat protection |
| I Load overcurrent protection | |
| Three phase currentunbalance protection | |
| Multiple ProtectionFunctions Extend Life | |
| Large Screen Display | LCD display |
| Real time monitoring ofcurrent working status | |
| After Sales | Professional technologyone-to-one guidance |
| NO. | Mark | Functional Description |
| 1 | P+ | Reference power supply +5V:Feed reference for external potentiometers |
| 2 | AI1 | Current analog input port1:DC0~20420mA(inputimpedance 1252),with 4-terminal GND to form an input loop. |
| 3 | AI2 | Voltage analog input port 2: 0~5V input/potentiometer input (center tap)/DC0~10V, and GND form the input circuit. 0~5V 0~10V no need to connect P+ |
| 4 | GND | Sianal common ground: analog signal negative terminal, switch signal common terminal |
| 5 | PWM | Signal Analog,PWM Input Port |
| 6 | 4-20mA Output | 4-20mA output+ |
| 7 | COM | 4-20mA output- |
| 8 | A | RS485 communication port,RS485+ |
| 9 | B | RS485 communication port,RS485- |
| 10 | SW1 | External start/stop control terminal:SW1and 12 terminal GND constitute the start/stop, when the two terminals are closed,the adjuster work |
| 11 | SW2 | Analog input port selection:SW2 and terminal 12 GND,closed to select analog input port 2; disconnected to selectthe input port |
| 12 | GND | Signal common ground:analog signal negative terminal,switch signal common terminal |
| 13 | NO | Output relay 1:according to the menu A basic parameters A07 function selection can be used as an output signal,or fault alarm output signal No.,load capacity AC240V/5A,DC24V/5A NO:Normally open NC:Normally closed |
| 14 | COM | |
| 15 | NC | |
| 16 | NO | Output relay 2:according to the menu A basic parameters A08 function selection can be used as an output signal,or fault alarm output signal No.,load capacity AC240V/5A,DC24V/5A NO:Normally open NC:Normally closed |
| 17 | COM | |
| 18 | NC | |
| 19 | L | External AC 220V power supply |
| 20 | N |
Basic application wiring: 4~20mA control signal input positive to terminal 2 Al1, negative to terminal
4 GND. start terminals 10 and 12 have been factory connected, default power on start.
lf you need to install a starting switch on the control cabinet, you can make 10 and 12 as a switch.
Safety reminder: it is recommended to use the alarm output function of the power conditioner when
designing the electrical wiring, the power conditioner for the load and power supply has a perfect
alarm function, when there is any abnormality, it can be the first time alarm output.
16KW/22KW/30KW/40KW/50KW/60KW/70KW/80KW/90KW/100KW/110KW/132KW/150KW/160KW175KW/200KW/220KW/250KW/280KW/300KW/320KW/350KW/400KW/450KW/500KW selection






SCR Heater Control wiring diagram